返回首頁
 
[ 攝影機 | TAKEX | JB series ]
This is zoom-up video camera that enlarged image can be obtained without using zoom lens at distant location.
》Overview
This is licenser camera that adopted CCD solid-state image sensor and can be utilized defect detection in manufacturing process and sensor of dimension measurement. Various types such as high-speed type whose scanning clock is 12MHz and high definition type whose pixels are 5000 are lined up.
》Features
  • TL-2048SJB (2048 pixels)
    High speed high sensitivity type
  • TL-5000JB (5000 pixels)
    High definition type
》Applications
  • Various defective points detection in sheet material
  • Pinhole detection of sheet material
  • Punch hole detection
  • Diameter, length measuring of tubular substance
  • As sensor for hole diameter measuring
  • Measuring of width Elength
  • Edge control
  • Loop control
  • Position measuring of substance
  • Image processing device
》Specifications
Model TL-2048SJB TL-5000JB
Light-sensitive element CCD CCD
Number of pixels 2048 5000
Pixel pitch x aperture 14 × 14 μm 7 × 7 μm
Length of the Light-receiving element 28.67 mm 35.0 mm
Video rate 1 to 10 MHz 1 to 12 MHz
Scanning rate (scan/sec) 100 to 4550 times
10 to 0.22 msec
100 to 2352 times
10 to 0.425 msec
Clock-to-video ratio 1 : 1 1 : 1
Driving clock input 1 to 10MHz
RS422 100 Ω terminal built in
TTL level 51 Ω terminal built in
Either is selected.
1 to 12MHz
RS422 100 Ω terminal built in
TTL level 51 Ω terminal built in
Either is selected.
Driving clock output TTL level output, impedance 51 Ω
Ratio of clock vs. video 1 : 1
Minimum clock number 2145 5098
Line transfer pulse input 10 to 0.22 msec
(at clock 10 MHz)
RS422 100 Ω terminal built in
TTL level 51 Ω terminal built in
Either is selected.
10 to 0.425 msec
(at clock 12 MHz)
RS422 100 Ω terminal built in
TTL level 51 Ω terminal built in
Either is selected.
Line transfer pulse output TTL level output, impedance 51 Ω
Video output 0 to 2.5 V (on-load 75 Ω)
Sensitivity V/lx.sec 30V 30V
Saturation exposure lx.sec 0.25 0.23
Dynamic range (Elements) 1500 *1 3000 *1
Output ununiformity MAX 10 % *2
Operation temperature range +12 V 500 mA
Operation humidity range 0 to +40oC
Storage temperature range 85 % RH (There should be no dew formed.)
Environmental condition -10 to +65oC
Weight 420 g
Lens mount Asahi K mount (Standard), Nikon mount (Optional)
Dimensional outline (body) 64 × 64 × 113 mm

 

   
 
Copyright © 2004 Power Assist Instrument Scientific Corp. All Right Reserved 