返回首頁
 
[ 攝影機 | SONY | XC-56BB ]

SONY 機械視覺/工廠自動化FA/光學自動檢測AOI 專用攝影機系列 |XC-56BB

搭配鏡頭:Computar、Fujinon、KOWA、Moritex、Myutron、Navitar、Optem、Pentax、Tamron、Kenko等。
應用領域:機械視覺用攝影機、工廠自動化FA用攝影機、光學自動檢測AOI用攝影機、 顯微鏡用攝影機、工業用攝影機等。

SONY 1/3 type progressive scan CCD" 攝影機
Model:Sony XC-56BB

 
XC-56BB

Features:
1/3 type progressive scan CCD
Non-TV format
Square pixel/ Full pixel read-out
VGA-class resolution image output,
      30 frames/sec.
High rate scanning function
External trigger shutter
    ● Restart/Reset
    ● Mode 1 (Non-reset mode)
    ● Mode 2 (Reset mode)
Various settings are available on the rear panel
Cable Longth: 2 m
Lead-free soldering


Dimensions:
   
 
Supplied Accessories:
 
 

Specifications:

 
XC-56BB
Image device
1/3 type Progressive Scan IT CCD
Effective picture elements(HxV)
659 (H) x 494 (V)
Effective lines(HxV)
647 (H) x 493 (V)
Output image
Output image size VGA class ( 647 (H) x 494 (V) )
Cell size
7.4 μm (H) x 7.4 μm (V)
Lens mount
NF-mout
Flange focal length
12.0 mmI
Sync system Internal / Externa
l (automatically switchied according to input signal)
External sync system input/output*1
HD/VD (HD/VD level: 2 to 5 Vp-p, 75Ω)
Allowable frequency deviation of external synchronization
±1 % (in horizontal synchronous frewuency)
H Jitter
Less than 20 ns
Scan lines
525-line/236-line
Video output mode
Normal: 1 -line sequentia output 29.97 fps /
Binning: F2 -line sequential output 59.94 fps
Video output
1.0Vp-p, sync negative, 75Ω unbalanced
Horizontal frequency
15.734 KHz
Output signal frequency (Hz)
29.97
Horizontal resolution
500TV lines
Sensitivity
400 lx F8 (γ= OFF, FIX GAIN (0 dB))
Minimum illumination
0.5 lx ( F1.4, γ= OFF, GAIN +18 dB )
Video S/N ratio
58 dB
Gain
Fixed/Manunally adjustable
Gamma
OFF (γ =1) (fixed)
White clip
820 mV ± 70mV
Shutter mode
Normal shutter, Restart/Reset, External trigger shutter (Mode1/Mode2)
Normal shutter speed
1/100, 1/125, 1/250, 1/500, 1/1,000, 1/2,000, 1/4,000, 1/8,000, 1/15,000 s
External trigger shutter
DIP switch settings: 1/100, 1/125, 1/250, 1/500,
1/1,000, 1/2,000, 1/4,000, 1/10,000, 1/25,000,
1/50,000, 1/100,000 s
Trigger pulse width settings: 1/4 to 1/100,000 s
External trigger
Polarity: +, Width: 2 μs to 250 ms,
Input impedance: 10kΩ or more
(H: +2 to 5.0V, L: 0 to +0.6V)
Power requirements
DC 12 V (+10.5 V to +15.0 V)
Power consumption 2.2 W
Dimensions CHU: 22 (W) x 22 (H) x 30 (D) mm
CCU: 29 (W) x 29 (H) x 67 (D) mm
Mass CHU: 40 g    CCU: 100 g
Operating temperature -5 to 45 °C
Storage temperature -30 to 60 °C
Performance guarantee temperature 0 to 40 °C
Operating humidity 20 to 80 % (no condensation)
Storage humidity 20 to 95 % (no condensation)
Vibration resistance 10 G (20 Hz to 200 Hz)
Shock resistance 70 G
   
 
Copyright © 2004 Power Assist Instrument Scientific Corp. All Right Reserved 
update: 2020-03-27